Residence:
U Sladovny 429
671 25 Hodonice
Phone: + 420 515 223 405, + 420 537 021 577
Fax: + 420 239 017 581
e-mail:
CEO:
Dipl. Ing. Oldřich Papoušek
Residence:
U Sladovny 429
671 25 Hodonice
Phone: + 420 515 223 405, + 420 537 021 577
Fax: + 420 239 017 581
e-mail:
CEO:
Dipl. Ing. Oldřich Papoušek

|
size 1100 x 1200x 250 mm, weight with full equipment 98 kg
|
|
1 - inductor AWG Z2R
2 - streamline P3 for heavy foam 3 - streamline C52 with tack
4 - tank with foamer 30 litre
5 - hydrant valve C52 6 - fire hose C52 / 20 or 30 m 7 - absorbent hose D25 for foam 8 - valve or cock 2"
9 - fittings, pipeline 10- hose drum
11- box: 1100 x1200 x 250 (mm) - special equipment by request: • inside heating cable
• 2 x 30 l foamer
- standard working pressure 4 - 6 bar
- at pressure 2 - 4 bar foam quality not guarantee (lower fire effect)
|
water supply from left suppressant output |
|
size 1100 x 1200x 250 mm, weight with full equipment 98 kg |
|
1 - inductor AWG Z2R
2 - streamline P3 for heavy foam 3 - streamline C52 with tack 4 - tank with foame 30 litre 5 - hydrant valve C52
6 - fire hose C52 / 20 or 30 m 7 - absorbent hose D25 for foam 8 - valve or nebo cock 2"
9 - fittings, pipeline 10- hose drum
11- box: 1100 x1200 x 250 (mm)
- special equipment by request: • inside heating cable
• 2 x 30 l foamer
-standard working pressure 4 - 6 bar
- at pressure 2 - 4 bar foam quality not guarentee (lower fire effect)
|
water supply from right
suppressant output |
|
IN CONFORMITY WITH § 4 , PAR. 3 ORDINANCE Nr.246 2001 Sb. IS THIS EQUIPMENT SPECIFIED SECURITY EQUIPMENT. ACCORDING TO § 5 , PAR. 4 IS COMPANY PZB s.r.o. PRODUCER OF FIRE SECURITY EQUIPMENT WITH ALL LAW APPRAISED CONTEXT. |
|
SERVICE INSTRUCTIONS - FOAM HYDRANT
IN CASE OF FIRE : |
|
| FireDeTec - DIMES |
|
|
D I M E S DIgital MEasuring System First continuous electronic control of volume measurement CO2
|
|||||||||||||||||||||||||||||||||||
Advantages:
absolute warranty
|
|
|||||||||||||||||||||||||||||||||||
|
patent valve with integrated pressure regulator
|
central control station and calibration unit
|
|||||||||||||||||||||||||||||||||||
|
connection to hose
FireDeTec valve output |
![]() |
integrated electronics for volume measurement - central control |
![]() ![]() |
|||||||||||||||||||||||||||||||||
![]()
|
||||||||||||||||||||||||||||||||||||
| OEL ROBUST antistatic hose resistant to oil products |
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
| UPEL - P antistatic absorbent resistant to aggressive fabrics |
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||
| Absorbent kit resistant to aggressive fabrics |
||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||